Sunday, June 2, 2019

Aluminium Heat Capacities

Aluminium Heat CapacitiesAimThe aim of the experiment was to retard the specific light up capacities, with uncertainties, of devil different materials for the purposes of this experiment, it was chosen to be aluminiumIntroductionSpecific heat capacity is defined as the quantity of heat energy, which will raise the temperature of unit sens (1kg) of a substance by 1K. It is usually denoted by c and expressed in J/(kg.K). (Joule per kilogram Kelvin).So, what is the human relationship between heat and temperature?It is usually expressed Q = m c T Heat energy = mass x specific heat capacity x temperature change, (c) existence the specific heat capacity. The relationship will not happen if there is a phase change due to heat either being added or removed, does not change the temperatureQ to the change of temperature T is given by Q = m c T Where Q = the change in heat energy. is the enthalpy, m = the mass c = specific heat capacity T = the change of temperature. Unit Jkg-1K-1.High sp ecific capacities occur in substance that take a forget me drug of heat energy and therefore have a long time to heat or cool down. The specific heat capacity of the sea is much(prenominal) greater than the land, so therefore more heat energy will be needed to heat it up by the same amount as the land. From the relationship mass x specific thermal capacity x temperature / time = current (amps) x p.d. (volts) .The ratio temperature rise or time bum be gotten from the graph slope of temperature which was plotted against time and this is how thermal capacity can be met.HypothesisCan the chosen method of investigation evolve a reliable value for the specific heat capacity of a metal fold?MethodApparatus Calibrated thermometerpower pack, Stop clock, VoltmeterLeads, rest (up to 1kg),Ammeter, Immersion heater Test metalsHeat proof matt and laggingThe immersion heater was connected to the power pack, which was set to 10V. The voltmeter and ammeter were set up so that they measured the potential difference and current going through the heater. Next the mass of the sample was recorded using the balance and the immersion heater was fixed in the test sample, followed by the thermometer and an initial temperature reading. Simultaneously the power pack was turned on and the stop clock started, and the heater was left to run for two minutes prior to the first recording. Recordings were taken from the voltmeter and ammeter every minute for a total of 15 intervals. The collected data was gathered into a table with the spare-time activity headings Following this the data was used to produce a graph of energy against temperature difference, from which the specific heat capacity can be determined. passe-partout mass 987.8gx-axisOriginal temperature, T1 20oCY-axisTemperature, T2Temperature change, T2-T1Voltmeter, VAmmeter, ATime, sEnergy, J26611.164.151205557.6827711.184.121808291.09301011.174.1624011152.1333.513.511,164.1530013894.20371711.134.1836016748.42402011.134.1942 019586.57432311.144.2048022458.2446.526.511.134.2254025363.0449.529.511.154.2160028164.9052.532.511.154.2166030981.3955.535.511.134.2372033897.5358.538.511.124.2378036689.33624211.134.2384039547.1264.544.511.124.2490042433.9267.547.511.114.2296045008.8370.550.511.114.24102048048.53Results Table 1See graph 3 for a plot of Energy, Q against the temperature difference, T. From this graph the gradient will be determined and the specific heat capacity for the metal found.Gradient of graph 3 units units Specific heat capacity of the metalunits units destructionThe hypothesis of Can the chosen method of investigation produce a reliable value for the specific heat capacity of a metal block? has been met ,more will be said and evaluated below.Evaluation Accuracy can be improved by the method of conducting several iterations of the experiment to gather enough information to produce a mean value for the specific heat capacity. Furthermore, the temperature was recorded using a liquid in glass thermometer with an accuracy of +/- 0.5 this lead to share errors in the temperature readings ranging from 2.5%- from In order to reduce these errors future experiments will be carried out using more accurate thermometer.

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.